上海金畔生物代理MiTeGen品牌蛋白结晶试剂耗材工具等,我们将竭诚为您服务,欢迎访问MiTeGen官网或者咨询我们获取更多相关MiTeGen品牌产品信息。
Sentinel Watchdog Kit G2 GAGG
Beam stop with X-ray detector provides real-time X-ray beam monitoring and dosing information without interfering with diffraction data collection.
- Upgraded Scintillator (GAGG) and Housing (Tungsten)
- Continuously monitor beamline stability.
- Calibrate X-ray beam intensity.
- Record intensity during data collection and determine exact sample radiation dose exposure.
- Micro-sized for minimum shadowing of the diffraction pattern.
SKU: DBSWD-2-GCategories: New Products, Sentinel™ Beamstops
Product Information
- Kit Contents
- Development
- Technical Specifications
- FAQ
- Instructions
Contents:
- (2) GAGG Beamstops – A beamstop with an embedded single-piece GAGG(Ce) crystal, with fiber-optic cable attachment
- (1) Diode – Cable assembly – Connects the fiber optic cable to the photodiode. Connects the output of the diode to the low-noise BNC cable.
- (1) Autoranging Picoammeter – Amplifies diode output and provides signal to PC via USB cable. Analog output voltage option available.
Sentinel™ Beamstop System was developed in collaboration with Diane Bryant, Simon Morton, and Marc Allaire at the Berkeley Center for Structural Biology at Lawrence Berkeley National Lab
Notes
Patent Pending |
Manufactured under exclusive license
with the Berkeley Lab — Lawrence Berkeley National Laboratory |
|
Sentinel™, Watchdog™, Diode beamstop™, and DBS™ are trademarks of MiTeGen LLC |
Beamstop
Beamstop Length: ~1.25 mm
Beamstop Diameter: ~1.25 mm diameter
Beamstop Material: Tungsten
Scintillator Material: Ce:GAGG (Cerium doped)
Fiber: fiber optic large diameter core glass optical fiber (365 micron core)
Fiber Length: no less than 300mm (custom lengths available)
Diode – Cable Assembly
Input: fiber optic scintillation photons via optical fiber
Output format: Diode current via low-noise BNC terminated cable
Cable length: ~25 cm
Auto-ranging Picoammeter
Input: fiber optic diode current via BNC connector
Output formats:
#1. Current sample values via USB cable
#2. Analog voltage -2V to 2V
Cable length: ~25 cm.
For any questions about MiTeGen Sentinel™ products please call +1 607 266 8877 or email [email protected]
FAQ’s
What beamline energy ranges can be measured?
The GAGG:Ce scintillator is responsive over a very broad range of energies. Contact us to discuss your needs.